DSA-N2B40 iSCSI Disk Array Series
  • Scale-out network storage solution: base unit with up to six disk shelf expansion units
  • Configurable RAID‑4 or RAID‑DP (Double Parity) data protection
  • Redundant hot-swappable power supplies and cooling fans
  • Four Gigabit Ethernet ports for high speed iSCSI connectivity
  • Modular design for ease of service
  • Central management through Web-based GUI
  • Overview
    Electrical requirements—one controller module
    Input voltage: 100 to 120 V Worst case, single PSU , System, two PSUs
    input current measured 3.62 A , 3.53 A
    input power measured 357 W , 345 W
    thermal dissipation 1217 BTU/h , 1177 BTU/h
    Input voltage: 200 to 240 V Worst case, single PSU , System, two PSUs
    input current measured 1.81 A , 1.8 A
    input power measured 347 W , 337 W
    thermal dissipation 1183 BTU/h , 1149 BTU/h
    Input power frequency 50 to 60 Hz , 50 to 60 Hz
    System hardware specifications
    Chassis 87.6 mm (3.45”), fits into 2U space, 19” IEC rack-compliant (449 mm, 17.6”)
    Power supplies Dual redundant, hot pluggable
    Max disk drives 12 x 1 TB SATA‑II drives
    Max net capacity ~7000 GB (RAID‑4 configuration)
    DDR2 memory (system RAM) 4096 MB
    Nonvolatile SDRAM (NVRAM) 256 MB—protects “in flight” transactions for 3 days in the event of a power loss
    Integrated I/O 4 x 10/100/1000 Gigabit Ethernet, copper
    Remote management (via LAN) Yes
    Mechanical
    Dimensions (H x W x D) 89 x 447 x 572 mm (3.5 x 17.6 x 22.5 in)
    Weight 27.215 kg (60 lb), full
    Space requirements
    Front—cooling 152 mm (6 in)
    Rear—cooling 305 mm (12 in)
    Front of chassis—maintenance 762 mm (30 in)
    Rear of chassis—maintenance 914 mm (36 in)
    Environmental
    Operating temperature +10 °C to +40 °C (+50 °F to +104 °F)
    Non-operating temperature -40 °C to +60 °C (-40 °F to +140 °F)
    Relative humidity 20 to 80%, non-condensing
    Acoustic level N/A
    Electrical requirements
    Input voltage: 100 to 120 V Worst case, single PSU , System, two PSUs
    input current measured 3.42 A , 3.22 A
    input power measured 341 W , 321 W
    thermal dissipation 1163 BTU/h , 1095 BTU/h
    Input voltage: 200 to 240 V Worst case, single PSU , System, two PSUs
    input current measured 1.63 A , 1.60 A
    input power measured 323 W , 309 W
    thermal dissipation 1103 BTU/h , 1054 BTU/h
    Input power frequency 50 to 60 Hz , 50 to 60 Hz
    System hardware specifications
    Chassis 3U, 19”-rack-mountable
    Power supplies Dual redundant, hot pluggable
    Max disk drives 14 x 1 TB SATA‑II drives
    Max net capacity ~7600 GB
    Shelf connectivity Fibre Channel: copper fiber
    Mechanical
    Dimensions (H x W x D) 133 x 447 x 552 mm (5.25 x 17.6 x 22 in)
    Weight 30.8 kg (68 lb), fully loaded
    Space requirements
    Front—cooling 153 mm (6 in)
    Rear—cooling 305 mm (12 in)
    Front of chassis—maintenance 559 mm (25 in)
    Rear of chassis—maintenance 305 mm (12 in)
    Environmental
    Operating temperature +5 °C to +40 °C (+41 °F to +104 °F)
    Non-operating temperature -40 °C to +60 °C (-40 °F to +140 °F)
    Relative humidity 20 to 80%, non-condensing
    Acoustic level 58 dBA at +23 °C