FPA‑1000‑UL Analog Addressable Fire Panel

FPA‑1000‑UL Analog Addressable Fire Panel
  • Support for up to 508 points on two analog addressable loops
  • Built‑in Ethernet connector for web‑browser based programming and ConettixIP Alarm-over-IP communication
  • Carbon Monoxide Detector (gas) support meets NFPA 720 (2009) requirements for visual and audible annunciation
  • Auto‑Learn mode for easy provisioning
  • On‑line help and off‑line programming capability provide simple configuration and service
 

Accessories

FMR-1000-RA LCD annunciator FPA-1000 without control

FMR-1000-RA LCD annunciator FPA-1000 without control

LCD annunciator without system control capability for use with the FPA‑1000 Analog Addressable Fire Panels

Commercial Type No.: FMR-1000-RA
Product No.: F.01U.066.880

 
FMR-1000-RCMD LCD annunciator FPA-1000 with control

FMR-1000-RCMD LCD annunciator FPA-1000 with control

LCD annunciator with system control capability for use with FPA‑1000 Analog Addressable fire Panels

Commercial Type No.: FMR-1000-RCMD
Product No.: F.01U.066.879

 
 
FPE-1000-SLC Plug-in SLC module for FPA-1000

FPE-1000-SLC Plug-in SLC module for FPA-1000

Provides a Signaling Line Circuit (SLC) for connection of analog devices to the FPA‑1000 Analog Addressable Fire Panels

Commercial Type No.: FPE-1000-SLC
Product No.: F.01U.073.062

 
D5070 Analog point programmer, hand-held

D5070 Analog point programmer, hand-held

Used to program address settings on EEPROM‑programmable analog devices

Commercial Type No.: D5070
Product No.: 4.998.800.577

 
 
FAA-325-2.5 Sample tube, duct 2.5'/76.2cm

FAA-325-2.5 Sample tube, duct 2.5'/76.2cm

2.5 ft. (762 mm) long sample tube for use with the FAD‑325, FAD‑325‑R, FAD‑325‑V2F, and FAD‑325-V2F‑R Analog Duct Detectors

Commercial Type No.: FAA-325-2.5
Product No.: F.01U.133.075

 
FAA-325-5 Sample tube, duct 5'/152.4cm

FAA-325-5 Sample tube, duct 5'/152.4cm

5 ft. (1.52 m) long sample tube for use with the FAD‑325, FAD‑325‑R, FAD‑325‑V2F, and FAD‑325‑V2F‑R Analog Duct Detectors

Commercial Type No.: FAA-325-5
Product No.: F.01U.133.076

 
 
FAA-325-10 Sample tube, duct 10'/304.8cm

FAA-325-10 Sample tube, duct 10'/304.8cm

10 ft. (3.05 m) long sample tube for use with the FAD‑325, FAD‑325‑R, FAD‑325-V2F, and FAD‑325‑V2F‑R Analog Duct Detectors

Commercial Type No.: FAA-325-10
Product No.: F.01U.133.077

 
FAA-325-B4 Analog sensor base, 4

FAA-325-B4 Analog sensor base, 4"

Is combined with analog addressable detectors that use the advanced digital communication protocol to provide early fire warning for life safety and property protection

Commercial Type No.: FAA-325-B4
Product No.: F.01U.133.061

 
 
FAA-325-B6S Analog sensor base with sounder, 6

FAA-325-B6S Analog sensor base with sounder, 6"

Contains an addressable sounder which provides an audible alarm in the immediate vicinity and only works in combination with one of the FAH‑325, FAI-325, or FAP‑325 analog sensors

Commercial Type No.: FAA-325-B6S
Product No.: F.01U.133.063

 
FAD‑325 Analog Duct Detector Housing

FAD‑325 Analog Duct Detector Housing

Housing for use in heating, ventilation and air conditioning systems (HVAC) that comes with an FAD‑325‑DH Analog Duct Smoke Detector Replacement

Commercial Type No.: FAD-325
Product No.: F.01U.133.072

 
 
FAD-325-DH Analog Duct Smoke Detector Replacement Head

FAD-325-DH Analog Duct Smoke Detector Replacement Head

Two‑wire replacement detector for the FAD‑325 and FAD‑325‑R duct housings has adjustable threshold smoke level and automatic compensation values. It has EEPROM addressing with the D5070, two polling and detector status LEDs for 360º view, and easy removal for cleaning and servicing.

Commercial Type No.: FAD-325-DH
Product No.: F.01U.133.074

 
FAH‑325 Analog Heat Detector

FAH‑325 Analog Heat Detector

Used in indoor environments with high ambient temperatures such as kitchens, boiler rooms, or drying rooms; compatible with 127 addresses

Commercial Type No.: FAH-325
Product No.: F.01U.132.985

 
 
FLM-325-2I4 Dual input module for FPA-1000

FLM-325-2I4 Dual input module for FPA-1000

Provides two independent contact monitoring circuits to monitor Normally Open (NO) or Normally Closed (NC) dry contact types of fire alarm devices

Commercial Type No.: FLM-325-2I4
Product No.: F.01U.133.068

 
FLM‑325‑2R4 Dual Relay Module

FLM‑325‑2R4 Dual Relay Module

Provides two independently‑controlled Form C contacts for a variety of Normally Open and Normally Closed applications

Commercial Type No.: FLM-325-2R4
Product No.: F.01U.133.069

 
 
FLM-325-CZM4 Conventional zone module for FPA-1000

FLM-325-CZM4 Conventional zone module for FPA-1000

Enables the FACP to interface and monitor up to 25 conventional devices depending on the device type such as two‑wire smoke detectors or pull stations

Commercial Type No.: FLM-325-CZM4
Product No.: F.01U.133.067

 

FLM‑325‑I4 Contact Monitor 4‑inch

Mounted to a cover plate for a 4‑inch square or double gang electrical back box; a bi‑colored LED provides module status; compatible with 127 addresses

Commercial Type No.: FLM-325-I4
Product No.: F.01U.133.066

 
 
FLM-325-ISO Short circuit isolator for FPA-1000

FLM-325-ISO Short circuit isolator for FPA-1000

Isolates a shorted section on a specific polling circuit from the rest of the system to minimize the loss of communication

Commercial Type No.: FLM-325-ISO
Product No.: F.01U.133.071

 
FMM-325A Analog manual station, single, red

FMM-325A Analog manual station, single, red

The single‑action manual station is UL listed for commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the address on the polling circuit by programming an EEPROM microchip with the D5070 Analog point programmer.

Commercial Type No.: FMM-325A
Product No.: F.01U.246.085

 
 
FMM-325A-D Analog manual station, double, red

FMM-325A-D Analog manual station, double, red

The double‑action manual station is UL listed for commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the address on the polling circuit by programming an EEPROM microchip with the D5070 Analog point programmer.

Commercial Type No.: FMM-325A-D
Product No.: F.01U.246.087